Microscan MINI Hawk Xi Uživatelský manuál Strana 251

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 388
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 250
MINI Hawk Xi High Performance Imager Us
er Manual 10-21
Camera and IP Setup
Increment Focus Position
The following example assumes a focus position setting of 400 (4”), with access to the
focus distance values shown in the imager response.
Send: <K526?>
Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533,
539,545,550,556,561,565,570,574,578,582,586,590,594,597,601>
The current focus position would be 410 (4.1”).
Send: <K525+>
Send: <K525?>
Response: <K525,447>
Decrement Focus Position
The following example assumes a focus position setting of 400 (4”), with access to the
focus distance values shown in the imager response.
Send: <K526?>
Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533,
539,545,550,556,561,565,570,574,578,582,586,590,594,597,601>
The current focus position would be 410 (4.1”).
Send: <K525->
Send: <K525?>
Response: <K525,264>
Definition: Increments the imager’s focus setting to the next focal distance supported
by the imager.
Note: Use the Focus Distance Table command <K526> to find the focal
distance settings supported by your imager.
Serial Cmd: <K525+>
Options: 200 (2”) to 600 (6”)
Definition:
Decrements the imager’s focus setting to the next focal distance supported
by the imager.
Note: Use the Focus Distance Table command <K526> to find the focal
distance settings supported by your imager.
Serial Cmd: <K525->
Options: 200 (2”) to 600 (6”)