MS-4X Imager User Manual
3-33
Communications
Preamble
Preamble Status
Preamble Characters
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K141h,,3C>
For >: <K141h,,3E>
For
, : <K141h,,2C>
See ASCII Character Entry Modifier for a detailed explanation of how to enter ASCII
characters as hex values.
Usage: Useful for identifying and controlling incoming data. For example, defining
the preamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Definition: Defines a one to four character data string that can be added to the front of
the decoded data.
Serial Cmd: <K141,status,preamble character(s)>
Default: Disabled
Options: 0 = Disabled 1 = Enabled (within any protocol)
Serial Cmd: <K141,status,preamble character(s)>
Default: ^M corresponds to: carriage return.
Options: To enter control characters within a serial command, hold down the Ctrl
key while typing the desired character.
Example: <K141,1,CNTL-m> to enter the control character ^M.