Trigger Mode
4-4 MS-820 Industrial Bar Code Scanner User’s Manual
4–Read Cycle/Trig-
Trigger Mode
Continuous Read
Definition: The type of trigger event that will initiate the read cycle.
Serial Cmd: <Kgtrigger mode,trigger filter duration>
Default: Continuous Read
Options:
0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data & External Edge
Definition: In Continuous Read, trigger input options are disabled, the scanner
is always in the read cycle, and it will attempt to decode and transmit
every scan crossing a label.
When To Output and Noread options have no affect on Continuous
Read.
Usage: Continuous Read is useful in testing bar code label readability or
scanner functions. It is not recommended for normal operations.
Serial Cmd: <Kg0>