EZ Match User Manual
Pharmacode
Bar Width Status (Pharmacode)
Direction (Pharmacode)
Fixed Threshold Value (Pharmacode)
Definition: If set to Mixed, the imager will autodiscriminate between narrow bars and
wide bars. If set to All Narrow, all bars will be considered as narrow bars. If
set to All Wide, all bars will be considered as wide bars. If set to Fixed
Threshold, it will use the fixed threshold value to determine whether the
bars are narrow or wide. The Bar Width Status setting will be ignored
when the imager is able to tell the difference between the narrow and the
wide bars.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value>
Default: Mixed
Options: 0 = Mixed
1 = All Narrow
2 = All Wide
3 = Fixed Threshold
Definition: Specifies the direction in which a symbol can be read.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value>
Default: Forward
Options: 0 = Forward 1 = Reverse
Definition: Used when Bar Width Status is set to Fixed Threshold. Defines the
minimum difference in pixels that will distinguish a narrow bar from a wide
bar.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value>
Default: 10
Options: 1 to 65535