MS-2 CCD Reader User’s Manual 4-7
Read Cycle
Trigger Mode
Continuous Read
External Level
Definition: The Trigger is the event that initiates a read cycle.
Serial Cmd: <K200,trigger mode>
Default: Continuous Read
Options: 0 = Continuous Read
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Usage: Continuous Read is useful in testing symbol readability or reader functions.
It is not recommended for normal operations.
Definition: In Continuous Read, trigger input options are disabled and the reader is
always in the read cycle. If a single symbol stays within read range for
multiple read cycles, its data will be transmitted repeatedly until it leaves
the read range.
The reader sends replies to serial commands that require responses when
symbol data is transmitted.
Note: No Read
options have no affect on
Continuous
Read.
Serial Cmd: <K200,0>
Usage: This mode is effective in an application where the speeds of the conveying
apparatus are variable and the time the imager spends reading each object
is not predictable. It also allows the user to determine if a No Read has
occurred.
Definition: External Level allows the read cycle (active state) to begin when a trigger
(change of state) from an external sensing device is received. The read
cycle persists until the object moves out of the sensor range and the active
trigger state changes again.
Serial Cmd: <K200,2>
Initiate Read Cycle:
Object #1, moving in front of the
detector beam, causes a
change in the trigger state,
which initiates the read cycle.
End Read Cycle:
The same object, moving out of
the detector beam, causes
another change in the trigger
state, which ends the read cycle.