5-10 MS-2 CCD Reader User’s Manual
Code 128/EAN 128
Code 128/EAN 128
Minimum Symbol Length (Code 128/EAN 128)
Application Record Separator Character
(Code 128/EAN 128)
Usage: Code 128 is a smaller symbology useful in applications with limited space
and high-security requirements.
Definition: A very dense alphanumeric symbology. It encodes all 128 ASCII characters,
it is continuous, has variable length, and uses multiple element widths
measured edge to edge.
Serial Cmd:
<
K474,
status
,0,minimum symbol length,1
,1,0,
application record separator
character>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Minimum Symbol Length helps prevent truncations and increases data
integrity by ensuring that only one symbol length will be accepted.
Definition: This specifies the exact number of characters that the reader will recognize
(this does not include start, stop, and check characters). The reader
ignores any symbol not having the specified length.
Serial Cmd:
<
K474,
status
,0,
minimum symbol length
,1
,1,0,
application record separator
character>
Default: 0
Options: 0 to 32
Definition:
This is an ASCII character that serves as a separator in formatted output.
Serial Cmd: <
K474,
status
,0,minimum symbol length,1
,1,0,
application record separator
character>
Default:
NUL
Options:
Any ASCII character (7 bit)