HS-21/HS-41X Handheld Reader User’s Manual A-19
Appendices
0xEE 0xEE 0xEE 0xEE 0x49 0x00 0x00 0x03 0x3C
This executes the info command, “I” in text command format. Since it does not have any
data datum associated with it, 0x00 following 0x49 (ASCII “I”) but before the reserved field
and CRC14 (0x00 0x03 0x3C) indicating it has no dataopt.
0xEE 0xEE 0xEE 0xEE 0x50 0x04 0xC4 0x32 0x35 0x35 0x00 0x43 0x3C
This will change the reader to trigger-read mode, “P(C4)255” in text command format.
0x50 is the command-type, 0x04 indicates that following 4 bytes are the data option with
0xC4 being the register that needs to be updated and 0x32 0x32 0x35 being the new value.
0xEE 0xEE 0xEE 0xEE 0x50 0x03 0xA9 0x35 0x63 0x00 0x77 0x6B
This will change the reader Bypass Gain to 92 (0x5c) percent, “P(A9)5c” in text command
format. 0x50 is the command-type, 0x03 indicates that the following 3 bytes are the data
option with 0xA9 being the register that needs to be updated and 0x35 0x63 (5c) being the
new value.
0xEE 0xEE 0xEE 0xEE 0x50 0x07 0x28
0x31 0x45 0x41 0x29 0x46 0x41 0x00 0x14 0x18
This will change Good Read Duration to 250ms, “P(1EA)FA” in text command format. In
this case the register 1EA is more than one byte can hold; the register is converted to its
individual ASCII hex value bounded by 0x28 and 0x29, underlined above.