HS-21/HS-41X Handheld Reader User’s Manual A-27
Appendices
Reader Settings Table
Reg Setting Name
Default
(Hex)
Comment
04 Continuous Illumination During Read 0
0: Minimal Illumination
1: Leave Illumination On Until End
Read Cycle
Leave illumination on during read.
08 Reader Packet Format 1
1: Raw
2: Packet Mode Version 1
For example, USB “two-way” native:
1B: 5 (USB Native)
08: 2 (packet mode)
42: 1 (expect response)
Also see registers: 1B, 42
0A NEC 2 of 5 Symbology
1 Binary Dip Switch
Note: All symbol lengths greater than 2
are always enabled when NEC 2 of 5
Decoding is enabled.
Bit Controls Value
0
NEC 2 of 5
Decoding
0: Disabled
1: Enabled
1
Checksum
checking
0: Disabled
1: Enabled
2
Strip checksum
from result
0: Disabled
1: Enabled
3
1 Digit Symbol
Allowed
0: Disabled
1: Enabled
4
2 Digit Symbol
Allowed
0: Disabled
1: Enabled