Message Output
8-10 MS-3 Laser Scanner User’s Manual
8–Data Outputs
No Symbol Message
No Symbol Status
No Symbol Message
Definition: When enabled, sends a message to the host whenever an object is
detected but no bar code symbol is detected.
The No Symbol output is tied to the transition counter. If during a read
cycle no symbol is decoded and the required setting for the Transition
Sample Threshold is NOT met, a user defined message will be sent to
the host. See “Minimum Bar Transitions” on page 6-13.
Usage: Useful in determining if an object has an attached bar code symbol.
Serial Cmd: <K716,no symbol status,no symbol message>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K716,no symbol status,no symbol message>
Default: NOLABEL
Options: Up to seven ASCII characters (except NUL)