Chapter A Appendices
MS-3 Laser Scanner User’s Manual A-7
A–Appendices
Under-temperature <K403,degrees,message>
Laser Overcurrent <K404,message>
Laser Undercurrent <K405,message>
Power-on/Resets Counts <K406,powerups,resets>
Time Since Last Reset <K407?> returns: hours,minutes (read only)
Present Operating
Temperature
<K408?> returns: deg (read only)
Narrow Margins/
Symbology ID
<K450,narrow margins status,symbology identifier>
Background Color <K451,background color>
Code 39
<K470,status,check digit status,check digit output status,large intercharac-
ter gap,fixed symbol length status,fixed symbol length,full ASCII>
Codabar
<K471,status,start & stop match,start & stop output,large intercharacter
gap,fixed symbol length status,fixed symbol length,check digit type,check
digit output>
Interleaved 2 of 5
<K472,status,check digit status,check digit output,length 1,length
2>
UPC/EAN
<K473,UPCstatus,EAN status,supplementals status,separator sta-
tus,separator character,supplemental type>
Code 128 <K474,status,fixed symbol length status,fixed symbol length,,,,,,>
UCC/EAN-128
<K474,,,,UCC/EAN-128 status,output format,application record sepa-
rator status,application record separator character,application record
brackets,application record padding>
Code 93 <K475,status,fixed symbol length status,fixed symbol length>
Pharmacode
<K477,fixed bar length status,fixed bar length,min. no. of bars,bar
widths,forward/reverse>
Scan Speed <K500,scan speed>
Bar Detection <K502,(not used),minimum symbol transitions,maximum element>
Gain/Tracking <K504,gain adjustment,AGC sampling,AGC min,AGC max>
AGC Settings <K505,transition counter status,transition counter threshold>>
Focus <K508,focusposition,zero position>
Beeper Output <K702,beeper output>
Output 1 <K720,output on,polarity,pulse width,output mode,number to output on>
Output 2 <K721,output on,polarity,pulse width,output mode,number to output on>
Output 3 <K722,output on,polarity,pulse width,output mode,number to output on>
Command Title Format