Auxiliary Port
2-6 MS-3 Laser Scanner User’s Manual
2–Communications
Auxiliary Port
Note: The aux port cannot be used when the host port is set to RS422 or Multidrop.
As with the host port parameters, the auxiliary terminal’s settings (baud rate, parity,
stop bits, and data bits) must be identical with those of the auxiliary device.
Note: The aux port cannot be used when the host port is set to RS422 or Multidrop.
Auxiliary Port Modes
Definition: An auxiliary port connects the scanner to a remote display or to other
scanners that can display or transfer data.
Usage: These commands set the communication parameters with the auxiliary
port which can be used to configure menus, send data to the host, dis-
play data transmissions originating from the host of the scanner, and
relay data from other scanners set in tandem (daisy chained). If the
scanner’s host port needs to be dedicated to the host, but configuration
must be done on the fly, the auxiliary port can be set to accept configu-
ration changes by Command Processing (page 2-10).
Definition: Determines the flow of data between the auxiliary port device(s), the
scanner, and the host.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default: Disabled
Options: 0 = Disabled
1 = Transparent
2 = Half duplex
3 = Full duplex
4 = Daisy chain
5 = Command Processing