Code 128
5-20 MS-3 Laser Scanner User’s Manual
5–Symbology
Code 128
Code 128 Status
Fixed Symbol Length Status (Code 128)
Fixed Symbol Length (Code 128)
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to
take effect.
Definition: A very dense alphanumeric symbology. It encodes all 128 ASCII char-
acters; it is continuous, has variable length, and uses multiple element
widths measured edge to edge.
Usage: Code 128 is useful in applications with tight spots and high security needs.
Serial Cmd: <K474,status,fixed symbol length status,fixed symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled, the scanner will check the symbol length against the
symbol length field. When disabled, any length would be considered a
valid symbol.
Serial Cmd: <K474,status,fixed symbol length status,fixed symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the exact number of characters that the scanner will recognize
(this does not include start and stop and check digit characters). The
scanner ignores any symbol not having the specified length.
Usage: Fixed Symbol Length helps prevent truncations and increases data
integrity by ensuring that only one symbol length will be accepted.
Serial Cmd: <K474,status,fixed symbol length status,fixed symbol length>
Default: 10
Options: 1 to 64