Chapter 4 Read Cycle/Trigger
MS-3 Laser Scanner User’s Manual 4-15
4–Read Cycle/Trig-
Read Cycle
Note: When to Output must be set to End of Read Cycle before this command can
be active.
End of Read Cycle Mode
Note: When operating in Continuous Read or Continuous Read 1 Output, the
scanner is always in the read cycle.
Timeout
Definition: The read cycle is the time during which the scanner will attempt to read
and decode a symbol. At the end of a read cycle the scanner stops
reading symbols and sends the symbol data or noread message to the
host.
Definition: A read cycle can be terminated by a new trigger, a timeout, or a combi-
nation of both.
Serial Cmd: <K220,end of read cycle,timeout duration>
Default: Timeout
Options: 0 = Timeout
1 = New Trigger
2 = Timeout & New Trigger
Definition: Timeout ends the read cycle when the time set in Timeout elapses or
“times out.
If in Continuous Read 1 Output, a timeout initiates a new read cycle
and allows the same symbol to be read again.
With either External Edge, Serial Data, or Serial Data & Edge
enabled, a timeout ends the read cycle and symbol data or a noread
message is sent to the host.
With External Level enabled, the read cycle does not end until the fall-
ing edge trigger or a timeout occurs. The next read cycle does not begin
until the next rising edge trigger.