Chapter 7 Calibration Database
MS-880 Industrial Long Range Scanner User’s Manual 7-3
7–Calibration Data-
Calibration Database by ESP
To Load the current settings obtained from autocalibration into the database:
Perform the autocalibration procedures described in Autocalibration by ESP” on page
6-4.
1. Click on autocalibration menu and the Database tab as shown in
figure 7-1.
2. Move the Database Index Indicator to the Index of your choice by clicking on
the arrows in the Database Index Selector.
3. Click on the Load Current to Database button.
This will put the Focus, Gain, and Tracking settings that reside in the Main tab
into the database index.
4. Repeat this procedure for other indexes.
You can also enter in individual values in any of the seven indexes by double-click-
ing anywhere on the index row and making changes in the popup window, or by
returning to the Main tab in Autocalibration and typing in the values of your choice.
Database index settings can be applied later in operation. See Chapter 8, “Optoelec-
trics.
Figure 7-1 Database Menu
Database
Index
Selector
Database
Index
Indicator