Ordered Output/Filtering
13-12 MS-880 Industrial Long Range Scanner User’s Manual
13–Output Format
Ordered Output/Filtering by Embedded Menu
Ordered Output/Filtering by Serial Command
Filter #
Code Type
Length
Embedded
Menu:
Definition: The filter sequence number from 1 to 12
Serial Cmd: <K744,filter#,code type,length,wildcard character,placeholder char-
acter,data>
Default: 0
Options: Range 1 to 12
Definition: User-assigned code type that the scanner will search for.
If a match is found, the scanner then checks Length.
Serial Cmd: <K744,filter#,code type,length,wildcard character,placeholder char-
acter,data>
Default: 0
Options: (Same as available in the Code Types setup menus)
Definition: User-assigned code length that the scanner will search for.
If the length is found, the scanner then checks Wild Card.
Serial Cmd: <K744,filter#,code type,length,wildcard character,placeholder char-
acter,data>
Default: 0 (any length)
Options: 0 to 128