Chapter 14 Discrete I/0
MS-880 Industrial Long Range Scanner User’s Manual 14-5
14–Discrete I/0
Output 1
Output On
Note: If Output On is set to Mismatch Or Noread, Match, or Mismatch, a transi-
tion (switching) will not occur unless Matchcode Type is enabled and a master label
is loaded into memory.
Mismatch or Noread
Match
Mismatch
Definition: Sets the discrete output functions for specific user-selected conditions.
Usage: This option provides switching to host software to control external
devices such as PLCs and relays. It is useful for routing and sorting and
to prevent mis-packaging and mis-routing.
Definition: Allows the user to set the conditions under which an output (or out-
puts) will be activated.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>
Default: Noread
Options: 0 = Mismatch Or Noread
1 = Match (or good read)
2 = Mismatch
3 = Noread
4 = Trend Analysis
Definition: Activates discrete output when the bar code data does not match that
of the master label or the bar code has not been decoded before the
end of the read cycle.
Definition: Activates a discrete output when the bar code data matches the master
label.
Note: If you want to output for a good read and Matchcode is not
enabled, you can enable any output for Match.
Definition: Activates a discrete output whenever the bar code data does not match
that of the master label.