Chapter 2 Communications
MS-880 Industrial Long Range Scanner User’s Manual 2-19
2–Communications
Menu Mode
Important Note: Menu Mode is only used in special cases (see “Usage” below). In
normal use the correct mode for your device is automatically selected.
Definition: In VT-100 mode, keyboard arrow keys of a VT-100 terminal (or termi-
nal emulation) may be used. TTY uses a teletype protocol.
Note: Send this command from the port to be changed.
Usage: Only useful in a special cases where a user has a TTY device (desktop
computer, laptop, etc.) and wishes to use the space bar and enter keys
to navigate through the embedded menus.
Serial Cmd: <K103,IR status,IR timeout,menu mode>
Default: The IrDA port defaults to VT-100 mode.
Options: 0 = TTY
1 = VT-100