Microscan QX Hawk Uživatelský manuál Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 460
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
QX Hawk Industrial Imager User Manual 1-5
Quick Start
QX Hawk C-Mount
Important: When connecting Ultra-Lock cordsets to the QX Hawk C-Mount and QX-1,
align the pins first and then push the connector into place. Do not twist
the connectors, as
this will bend the pins.
Important: Do not attempt to power more than four imagers with a single power supply in
a daisy chain configuration. Add a QX-1 and one power supply for every four additional
imagers in the daisy chain.
RS-232
Connect the Serial Communication Cable from “A” on the QX Hawk C-Mount to “2” on
the QX-1.
Connect the host cable from “1” on the QX-1 to the host computer.
Connect the photo sensor to “T” on the QX-1.
Connect the power supply to “3” on the QX-1.
Plug in the power supply.
Ethernet
Note:
The QX Hawk C-Mount does not require an Ethernet crossover cordset, because the
imager itself performs automatic internal crossover (transmit-to-receive switching). Microscan
offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02).
Connect the Ethernet Cable from “B” on the QX Hawk C-Mount to the network.
Connect the photo sensor to “T” on the QX-1.
Connect the power supply to “A” on the QX Hawk C-Mount.
Plug in the power supply.
1
2
3
5
6
8
Serial Standalone (with QX-1)
Ethernet Standalone (with QX-1)
1
2
3
7
6
8
Zobrazit stránku 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 459 460

Komentáře k této Příručce

Žádné komentáře