5-36 QX Hawk Industrial Imager User Manual
Communication
Array Communication Modes
Mode
Daisy Chain
When set to Daisy Chain, follows Microscan Daisy Chain protocol.
Note: Daisy Chain can also be autoconfigured by sending the Daisy Chain Autoconfigure
serial command.
Source
Defines the communication port.
Daisy Chain ID Status
When enabled, the imager will append a two-character prefix to each imager in the array.
This allows the user to identify which imager sent the data.
Note: Daisy Chain ID will automatically disable Symbol Data Output, Extended Data, and
Diagnostics Output for the Source Port.
Symbol Data Output will be automatically enabled, Extended Data will be automatically
enabled, and Diagnostics Output will be automatically disabled for the Destination Port.