5-54 QX Hawk Industrial Imager User Manual
Read Cycle
End of Read Cycle
The read cycle is the time during which the imager will attempt to decode a symbol. A read
cycle can be ended by a timeout or a new trigger, or a combination of the two.
End of Read Cycle Mode
Note: When operating in Continuous Read or Continuous Read 1 Output, the imager is
always in the read cycle.
Timeout
Typically used with Continuous Read 1 Output and Serial Data and Edge.
It is effective in highly controlled applications when the maximum length of time between
objects can be predicted. It assures that a read cycle ends before the next symbol
appears, giving the system extra time to decode and transmit the data to the host.
Timeout ends the read cycle, causing the imager to stop reading symbols
and send the
symbol data or No Read message when the time set in
Timeout
elapses (times out), if
When to Output Symbol Data is set to End of Read Cycle.
If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same
symbol to be read again.
With External Edge, Serial Data, or Serial Data and Edge enabled, a timeout ends the
read cycle and symbol data or a No Read message is sent to the host.
With External Level enabled, the read cycle does not end until the falling edge trigger
occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.