A-106 QX Hawk Industrial Imager User Manual
Using EtherNet/IP
NET and MOD LED Indicators
MOD (Module)
NET (Network)
Indicator State Summary Requirement
Microscan
Implementation
Steady OFF No power
If no power is supplied to the device, the
module status indicator will be steady
OFF.
Per requirement
Steady GREEN
Device
operational
If the device is operating correctly, the
module status indicator will be steady
GREEN.
Per requirement
Steady RED Major fault
If the device has detected a non-recoverable
minor fault, the module status indicator
will be steady RED.
Safe Mode: Basic
comm. only. Scanning
system non-functional.
Flashing GREEN /
RED
Self-test
While the device is performing its power-up
testing, the module status indicator will
be flashing GREEN / RED.
Per requirement.
Indicator State Summary Requirement
Microscan
Implementation
Steady OFF
No power, no
IP address
If the device does not have an IP
address (or is powered off), the network
status indicator will be steady OFF.
Per requirement.
Before device has
acquired an IP
address via DHCP.
Flashing GREEN No connections
If the device has no established connections,
but has obtained an IP address, the
network status indicator will be flashing
GREEN.
Per requirement.
After device has
acquired an IP
address (static or
DHCP).
Steady GREEN Connected
If the device has at least one established
connection (even to the Message
Router), the network status indicator will
be steady GREEN.
Per requirement.
Flashing RED
Connection
timeout
If one or more of the connections in
which the device is the target has timed
out, the network status indicator will be
flashing RED.
Per requirement.
Steady RED Duplicate IP
If the device has detected that its IP
address is already in use, the network
status indicator will be steady RED.
Not implemented.
Flashing GREEN /
RED
Self-test
While the device is performing its
power-up testing, the module status
indicator will be flashing GREEN / RED.
Per requirement.