
A-48 QX Hawk Industrial Imager User Manual
Serial Commands
Fixed Symbol Length Status (Codabar)
Symbol Length (Codabar)
Check Character Type (Codabar)
Check Character Output (Codabar)
Interleaved 2 of 5
Status (Interleaved 2 of 5)
Check Character Status (Interleaved 2 of 5)
Serial Cmd:
<
K471,
status,start/stop match,start/stop output,large intercharacter gap,
fixed
symbol length status
,symbol length,check character type,check character
output>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default: 10
Options: 1 to 128
Serial Cmd: <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default: 0 = Disabled
Options: 0 = Disabled
1 = Mod 16
2 = NW7 (Mod 11)
3 = Both Mod 16 and NW7 (Mod 11)
Serial Cmd: <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K472,status,check character status,check character output status,symbol
length #1,symbol length #2,guard bar status,range mode status>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K472,status,check character status,check character output status,symbol
length #1,symbol length #2,guard bar status,range mode status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Komentáře k této Příručce