Calibration Data
7-12 MS-9 Scanner User’s Manual
Calibration Data
Following a static or dynamic test, see the OMR DATA area to view Margin, Bar
Width, Cell Width, and Good Reads.
The bottom window presents the current triggered data. This serves to give you an idea
of consistency and variations.
You can also switch between Binary and Hexidecimal presentation of decoded data.
See and adjust calibration parameters in the Calibrated Data section of the OMR menu.
Calibrate Delay Status
Definition: When Calibrate Delay Status is enabled, the scanner will attempt to set
the delay time (or pulse) automatically.
Usage: This is useful if your symbols arrive at irregular times.
Serial Cmd: <KPcalibrate delay status,auto frame status,avg bar width,avg cell
width,leading margin,scan count value>
Default: Enabled
Options: 0 = Disabled 1 = Enabled