Send/Receive Options
2-8 MS-9 Scanner User’s Manual
Send/Receive Options
To access save and receive options, from the Configuration views click the
Send/Recv button:
You can also access this selector by right-clicking in any of the configuration views.
Saving
You have 3 choices for saving:
1. Send, No Save.
This saves ESP settings to current
memory.
2. Send and Save.
This activates all changes in cur-
rent memory and saves to the scanner for power-on. (Similar to the <Z> com-
mand.)
3. Send and Save, Including Factory. Includes all settings including changes to
factory settings.
For Multidrop setup, see “Multidrop Communications” on page A-32.
For Matchcode setup, see Chapter 6, “Matchcode.”
For more on defaulting and saving settings, see “Defaulting/Saving/Initializing” on
page A-21.
Receiving
From the Send/Recv selector select Receive Scanner Settings.
This is useful if you want to receive (upload) the scanner’s settings and save them as a
computer file for later retrieval and to verify that your ESP settings have been saved or
that you have not saved any unwanted changes that you or someone else previously
made in ESP.
Defaulting
When you select Default Current... or Default all ESP... you are only defaulting the
ESP settings. To default the scanner, see
“Defaulting/Saving/Initializing” on page
A-21 for a more information.