Microscan MS-96 Uživatelský manuál Strana 129

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 226
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 128
Chapter 8 I/0 Parameters
MS-9 Scanner User’s Manual 8-13
Output Mode
Pulse
Latch Mode 1 (Unlatch on Discrete Input 1)
Latch Mode 2 (Unlatch Opposite Condition)
Latch Mode 3 (Unlatch Re-enter Read Cycle)
NOTE: All of the Output On modes are inhibited when any Output on Warning is
active for Output 1 (see <K713> command).
Definition: Sets the condition in which the discrete output is de-activated.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend analy-
sis mode,trigger evaluation period,number to output on,decodes per
trigger>
Default: Pulse
Options: 0 = Pulse
1 = Latch Mode 1
2 = Latch Mode 2
3 = Latch Mode 3
Definition: This is the default mode of operation in which the programmable output
is activated when the Output On condition has been met and held active
for the duration of the selected pulse width.
Definition: The programmable output is active when the Output On condition has
been met and held active until the discrete Input 1 has been activated.
Definition: The programmable output is activated when the Output On condition
has been met and held active until the opposite condition selected under
Output On has been met.
For example, if Noread is enabled under Output On, the programmable
output will go active upon a noread and remain active until the opposite
condition, a good read, occurs.
Definition: The programmable output is active when the Output On condition has
been met and is held active until a new read cycle begins.
Zobrazit stránku 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 225 226

Komentáře k této Příručce