Chapter 9 Diagnostics
MS-9 Scanner User’s Manual 9-11
Low Temperature Threshold
A message can be defined that will display when a user-set Low Temperature
Threshold has been reached. The message repeats once every 30 minutes until the
condition is corrected. This value is a reference to the external ambient temperature in
the environment around the scanner.
Low Temperature Degrees
Low Temperature Message
Usage: Helps ensure that the scanner is being used within its temperature speci-
fication.
Definition: The user can set a low temperature value that, whenever the ambient
temperature falls below it, causes a low temperature message to be dis
-
played. If Low Temperature Threshold is set to zero, the warning
message will be disabled.
Serial Cmd: <K403,degrees,message>
Default: Celsius
Options: 0° to 50°, zero disables.
Definition: The user can enter a message of up to 10-characters that will be dis-
played whenever the ambient temperature falls below the Low Temper-
ature Threshold.
Serial Cmd: <K403,degrees,message>
Default: LOW_TEMP
Options: Any 1 to 10 character ASCII string except NUL, <, or >.