5-10 MS-4 Imager User’s Manual
Trigger Mode and Duration
Trigger Filter Duration
Note: If Trigger Mode is set to External Edge, the Imager will trigger only after the active
state has been delayed for the specified filter duration.
Note: If Trigger Mode is set to External Level, the Imager will trigger once the active
state has been delayed for the specified filter duration after the appearance of an object’s
active edge.
In addition, the active state must be delayed for the specified filter duration after the disappearance
of the object’s falling edge for the trigger to be rendered inactive.
Usage: Trigger Filter Duration allows the Imager to disregard false trigger
events.
Definition: When Trigger Mode is set to either External Edge or External Level, the
read cycle’s active state must be delayed until the specified filter duration
has elapsed. The Imager will trigger at the end of that duration.
Serial Cmd: <K200,trigger mode,trigger filter duration>
Default: 313 (x 32µs = 10.24mS)
Options: 1 to 65535 (corresponding with 32µs to 2.097seconds in 32µs steps)