7-14 MS-4 Imager User’s Manual
2D Symbology Qualification
Orientation Mode
Disabled
Decoded messages are output, but no attempt is made to qualify symbols or to output
Bad Symbol or No Symbol messages.
Bad/No Symbol Output
Checks first for decodes. If no symbol is decoded, checks for symbol orientation. If
Orientation
Value is satisfied, a Bad Symbol message is output. If not satisfied, a No Symbol message
is output.
Object Qualification
Checks first for matches to symbol Orientation Value. If qualified, attempts to decode. If no
decodes are found within the specified read cycle parameters, outputs a
No Read
message.
Enable Both
Same as Object Qualification, except that if Orientation Value is satisfied but the symbol
is not decoded, then a Bad Symbol message is output; if not satisfied, a Bad Symbol
message is still output.
Definition: Sets the orientation value.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension
tolerance,orientation mode,orientation value>
Default: Disabled
Options: 0 = Disabled
3 = Enable Both
1 = Bad/No Symbol Output 2 = Object Qualification