10-22 MS-4 Imager User’s Manual
Number of Symbols in Field of View
Number of Symbols in Field of View
Note: When the number of symbols in the field of view is set to 1, codeword stitching from
all scaled image processes is allowed for PDF417 and MicroPDF417.
Note: This variable is used in Fast Linear Mode. FLM usually considers the whole image
as one candidate, but when Number of Symbols in Field of View is set to 2, FLM will try
to locate the candidates first and then decode. The symbols cannot be side-by-side--they
must be parallel.
Definition:
This command allows the user to determine how
FLM
will behave in relation
to the candidate symbols in the field of view.
Serial Cmd: <K518,number of symbols in field of view>
Default: 0
Options: 0 = Any number of symbols
1 = One symbol
2 = More than one symbol