3-16 MS-4 Imager User’s Manual
Auxiliary Port Connections
Command Processing Mode
Usage: Allows a user to send configuration settings from the host port to the auxiliary
port.
Definition: When enabled, Command Processing Mode allows commands to be
entered via the auxiliary port and direct externally triggered read cycle data
in one of two ways:
Bar code data, including the serial trigger (if used), will be transmitted to
the last port from which a command was sent.
If the last command came from the host port, then externally triggered
read cycle data will only be output to the host port.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status,daisy chain i.d.>
Options: 5 = Command Processing