MS-4 Imager User’s Manual 7-33
I/O Parameters
Trend Analysis Mode
Mismatch
Output will be activated when the number of mismatches equals the value entered for
Number to Output On within the trigger window selected in Number of Triggers.
No Read
Output will be activated when the number of No Reads equals the value entered for
Number to Output On within the trigger window selected in Number of Triggers.
Decodes/Trigger
Output will be activated when the number of decodes equals the value entered for
Number to
Output On
within the trigger window selected in
Number of Triggers
.
Bad Symbol
Output will be activated when the number of
Bad Symbol
occurrences equals the value
entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
No Symbol
Output will be activated when the number of
No Symbol
occurrences equals the value
entered for
Number to Output On
within the trigger window selected in
Number of Triggers
.
Definition: Sets the trend condition (Mismatch, No Read, or Decodes/Trigger) that
will activate the output.
Serial Cmd:
<
K780,trend analysis mode
,trigger evaluation period,number to output on,
decodes/trigger threshold>
Default: No Read
Options: 0 = Mismatch
3 = Bad Symbol
1 = No Read
4 = No Symbol
2 = Decodes/Trigger