Microscan MS-4 Uživatelský manuál Strana 165

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 390
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 164
MS-4 Imager User’s Manual 7-9
I/O Parameters
1D / Stacked Symbology Qualification
Minimum Number of Bars
Minimum Number of Qualified Scan Lines
Start/Stop Status
Definition: Sets the minimum number of bars to qualify linear symbols.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: 0
Options: 0 to 255 (0 is disabled)
Definition: Sets the minimum number of scans that have the required number of
bars set in Minimum Number of Bars.
Important: This is a percentage value, from 0 to 100.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: Disabled
Options: Any number from 0 to 100 (0 disables this feature).
Definition: When enabled, both Start and Stop characters need to be present to
qualify as a decodable symbol. In the case of PDF417, only a Stop needs
to be present.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Zobrazit stránku 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 389 390

Komentáře k této Příručce

Žádné komentáře