MS-4 Imager User’s Manual 9-11
Matchcode
New Master Pin
New Master Load Status
Definition: If Matchcode and New Master Pin are enabled and the new master pin
is momentarily connected to ground (must be held low for a minimum of
10 mS) master symbol information will be loaded into the database
based on the next read cycle that achieves a Good Read, starting with
Index 1. The Master Symbol Database will be loaded with all symbols
decoded in the read cycle as long as it does not exceed the Number of
Master Symbols parameter.
Serial Cmd: <K225,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: The new master status responds with the number of the next master
position to be loaded, where 0 represents “idle” or “no master to be
loaded.”
Example: If the user has the Number of Master Symbols set to 1, and
then either sends a <G> or toggles an active New Master Pin, the state
will be 1, and prior to reading and effectively loading position 1, the
response to <NEWM> would be <NEWM/1>. Once a symbol has been
read and loaded, the status will be cleared: <NEWM/0>.
Serial Cmd: <NEWM>