MS-4 Imager User’s Manual 7-45
I/O Parameters
Image Output
Good Read
If a Good Read condition is met during the read cycle, the image file corresponding with
the first Good Read will be output. The image file will immediately follow the read cycle
output and postambles. For a Good Read condition to occur, all symbols in the read cycle
must qualify.
No Read
If a No Read condition occurs during the read cycle, the image file corresponding with the
first No Read will output. The image file will immediately follow the read cycle output and
postambles. There are conditions in which the read cycle may have a No Read condition
but the image will not be output. For example, if the read cycle is looking for two No Read
symbols in the same image capture but one is a Good Read, the image will not be output,
because it is not considered a No Read image.
No Read or Good Read
If a No Read condition or a Good Read condition occurs, the first image of either kind will
be output.
Mismatch
If a Good Read occurs during the read cycle but the image is a Mismatch condition, the
first Mismatch image will be output.
Usage: This feature allows the user to select what read cycle condition triggers
the image file output.
Definition:
Used to output an image file when a specified read cycle condition has been
met, such as No Read or Good Read. When the read cycle is complete, the
normal read cycle output will occur, including any configured postamble or
preamble data. The read cycle will the check if image output is enabled, and
if the specified read cycle condition has been met. If both these conditions
are true, the image file will be output to the user-specified communication
port in the user-specified image file format.
Serial Cmd: <K739,image output mode,communication port,file format,jpeg quality>
Default: Disabled
Options: 0 = Disabled 1 = Good Read 2 = No Read
3 = No Read or Good Read 4 = Mismatch