14-10 MS-4 Imager User’s Manual
Output Filter Configuration
Filter Number
Symbology Type
Definition: This is the filter index number that represents the position of the symbol in
the data output at the end of the read cycle. This index number should be
entered along with the following filter settings for the predetermined symbol
position.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data,
unused,database index>
Options: 1 to 10
Definition:
Specifies the symbology type allowed to occupy this location in multi-symbol
output.
Note: To filter or order a symbol, the symbol must meet all the requirements
of the selected filter index.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data,
unused,database index>
Default: 0 (any symbology type)
Options: •0 = Any type
• 1 = Interleaved 2 of 5
•2 = Code 39
•3 = Code 128
• 4 = Codabar
•5 = UPC
•6 = PDF417
•7 = EAN 128
•8 = Code 93
•10 = GS1 DataBar
• 11 = MicroPDF417
• 12 = Composite
• 13 = BC412
• 14 = Data Matrix
• 15 = QR Code