MS-4 Imager User’s Manual 2-15
Using ESP
Send/Receive Options
To access Receive, Save and Default options, click the Send/Recv
button. You can also access these options by right-clicking in any of the
configuration views.
Receiving
From the Send/Recv menu, select Receive Reader Settings.
Caution: Do not select this option if you do not want to upload the Imager’s settings. For
example, if your ESP file has a number of custom settings that you want to maintain and
download into the Imager, these settings would be lost by choosing Yes.
This is useful if you want to receive (upload) the Imager’s settings and save them as a file
for future use. For example, if your Imager has settings that you do not want to change,
choosing Yes would allow you to load those settings to ESP and save them in an ESP file
for later retrieval.
Receiving the Imager’s settings will also assure that you will not be subsequently saving
any unwanted changes that you or someone else has made previously in ESP.
Saving
1. Send, No Save
(<A>)
This saves ESP
settings to current
memory.
2. Send and Save
(<Z>)
This activates all changes in current memory and saves to the Imager for power-on.
3. Send and Save as Customer Defaults
(<Zc>)
Use this option to save your own default settings for quick retrieval with a <Zrc>
command.
This option will be visible only if you had checked
Enable ‘Send and Save as Customer
Defaults’ in the ESP Preferences dialog.