Microscan MS-4 Uživatelský manuál Strana 173

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 390
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 172
MS-4 Imager User’s Manual 7-17
I/O Parameters
Output Indicators
The MS-4 Imager has a beeper and three LED arrays, as follows:
1. A target pattern of blue LEDs for centering the field of view, which is projected from
the front of the Imager .
2. An array of green LEDs projected from the front of the Imager that can be programmed
to flash in response to user-defined conditions.
3. A row of five status LEDs on the side of the Imager.
Green Flash Mode
Disabled
Green flash LEDs are disabled.
Good Read
Green flash LEDs will flash when a good read condition is met or when Matchcode is
enabled and a match occurs.
Usage: Used as a visual verification that a good read has occurred.
Definition: An array of green LEDs in the front of the Imager can be programmed to
flash in response to user-defined conditions.
Serial Cmd: <K750,green flash mode,target pattern status,green flash duration>
Default: Good Read
Options: 0 = Disabled
1 = Good Read
2 = Static Presentation
3 = Match
4 = Mismatch
5 = Strobe
Zobrazit stránku 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 389 390

Komentáře k této Příručce

Žádné komentáře