MS-4 Imager User’s Manual 7-29
I/O Parameters
Configurable Output 1
Note: If Output On is set to Match or Mismatch, a transition (switching) will not occur
unless Matchcode Type is enabled and a master symbol is loaded into memory.
Mismatch or No Read
Activates discrete output when the data does not match that of the master symbol or the
symbol has not been decoded before the end of the read cycle.
Match or Good Read
Activates a discrete output when the symbol data matches the master symbol.
Note: If you want to output for a good read and Matchcode is not enabled, you can
enable any output for Match.
Mismatch
Activates a discrete output whenever the symbol data does not match that of the master
symbol.
No Read
Activates a discrete output whenever the symbol data is not decoded before the end of the
read cycle.
Usage: This option provides discrete signalling to host software to control external
devices such as PLCs and relays. It is useful for routing, sorting, and to
prevent mis-packaging and mis-routing.
Definition: Sets the discrete output functions for specific user-selected conditions.
Allows the user to set the conditions under which an output (or outputs) will
be activated.
Serial Cmd:
<
K810,output on
,output state,pulse width,output mode>
Default: Mismatch or No Read
Options: 0 = Mismatch or No Read
3 = No Read
6 = Diagnostic Warning
1 = Match (or good read)
4 = Trend Analysis
7 = In Read Cycle
2 = Mismatch
5 = Symbol Quality