MS-4 Imager User’s Manual 14-5
Output Format
Format Extract
Output Index
Start Location
Length
Definition: Output Index refers to the database entry you wish to modify with this
command. A formatted output is built by extracting data from a symbol’s
original data output and/or inserting user-defined characters.
It may be helpful to think of individual indexes as positions in the final formatted
output you wish to build. Starting with index # 1, enter either an extract or insert
command to begin building your desired output string.
Then, with the next
index number, enter either an extract or insert command to continue building
the output string. Continue this process until you are finished building the
string.
Serial Cmd: <K740,output index,start location,length>
Options: 1 to 100
Definition: Defines the location within the symbol data where the character extraction
will begin. The first character extracted will also be the first character in the
sequence displayed in user-defined output.
Serial Cmd: <K740,output index,start location,length>
Default: 0
Options: 1 to n (maximum number of characters in the symbol data).
Definition: Defines the length (in consecutive characters) that will be extracted and
placed in user-defined output.
Serial Cmd: <K740,output index,start location,length>
Default: 0 (disabled; end of format cell array)
Options: 1 to n (maximum number of characters in the symbol data).