6-26 MS-4 Imager User’s Manual
GS1 DataBar (RSS)
DataBar Limited
DataBar-14
Note: Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked;
decode both stacked and non-stacked).
Usage: DataBar Limited is designed to be read by laser and CCD readers. It is
not recommended for omnidirectional slot scanners.
Definition: Encodes a smaller 14-digit symbol (74 modules wide) that is not omni-
directional.
Serial Cmd: <K483,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Used in the grocery, retail, and prescription drug industries where 14-digit
EAN item identification may be needed.
Definition: DataBar-14 (Reduced Space Symbology) is a fixed symbol length sym-
bology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is
96 modules wide. It can be stacked in two rows, it can read omnidirec-
tionally if printed in full height, or horizontally if height-truncated for small
marking.
Serial Cmd: <K482,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked;
decode both stacked
and non-stacked)